CIRCUIT DIAGRAM DW90.1, DW90.1OEM, DW90.2, DW90.C, DW90.3
80 840 68-01
Displays
DW90.1
Panel type DW90.1, L = LED, T = Push-button
DW90.1 OEM
Panel type DW90.1 OEM, L = LED, T = Push-button
DW90.2
Panel type DW90.2, L = LED, T = Push-button
DW90.3
Panel type DW90.3, T = Touch areas
L10
L11
L9
L8
T3
T6
L7
T5
T4
L3
L4
L5
L6
L2
L1
PROGRAM
T1
T2
T7
T2
L5
T7
L4
T6
L3
T5
L2
T4
L1
T3
T1
T8
Graph.
Area
L1
L2
L3
L4
L6
L5
T4
T1
T6T7T5
T3
L12
L9
L8
T2
T11
T7
T10
Failure
F:XX Last failure read out. F10 Overfillig, F11 Drain,
F12 Water inlet,F40 Valve leakage, F41 Temp.
stop,F42 Thermistor, F43 Pressure sensor,
F44 Turbidity sensor, F45 Diverter
START (T2)
Diagnostic
d:01 Mix valve and inlet valve on (1 sec delay
between mixventil and inlet valve)
d:02 Inlet valve on
d:03 Salt Valve on
d:04 Combi dispenser on
PROG (T1) d:05 Circulation and spolarmsväxlaren (if available)
shall alternate between positions 1 and 3 every
30 seconds
d:06 Circulation and heaters - max 75 ° C
d:07 Fan and vax actuatoor
d:08 Drain Pump on
d:00 No components on
START (T2)
Water inlet
P:0 Normal water intake, default
P:5 Water intake increased +5%
P:10 Water intake increased +10%
PROG (T1) P:15 Water intake increased +15%
L:0 Time, flow meter disconnected, inlet time: no of
pulses x 0.068 [s]
L:5 Timed water intake increased +5%
L:10 Timed water intake increased +10%
L:15 Timed water intake increased +15%
START (T2)
Variant,
DW90.1
U:1 DW90.1
U:2 DW90.1 OEM
Variant 1 and 2, the default setting
(temperature, drying)
U:3 DW90.1
U:4 DW90.1 OEM
Variant 3 and 4 (Temperature, Drying, Delayed
Start)
PROG (T1) U:5 DW90.1
U:6 DW90.1 OEM
Variant 5 and 6 (Set of time program,
Temperature, Drying, Time saving, Delayed
Start)
U:7 DW90.1 and
DW90.1OEM
Variant 7 (Set of time program, Temperature,
Drying, Time-saving, Upper Lower basket wash,
Delayed Start)
Variant,
DW90.2
U:1 Variant 1, the default setting (temperature,
drying)
U:2 Variant 2 (Temperature, Drying, Delayed Start)
PROG (T1) U:3 Variant 3 (Temperature, Drying, Delayed Start,
Set of time program)
U:4 Variant 4 (Temperature, Drying, Delayed Start,
Set of time program, Time saving)
START (T2)
Region
EU Region Europe, the default setting
PROG (T1) US Region USA
AU Region Australia
START (T2)
Fan
Sequence
Y:0 No fan sequence during wash cycle
PROG (T1) Y:1 Fan sequence during the wash cycle but not in
Normal program, the default setting
Y:2 Fan in sequence during the all wash cycles
START (T1)
TDE & HWC,
only DW90.2
A:0 Turbo Drying Express and Heat Water Circuit
off, default setting
PROG (T1) A:1 Turbo Drying Express on
A:2 Heat Water Circuit on
START (T2)
ECO, only
DW90.1
E:0 ECO off, the default setting
PROG (T1) E:1 ECO on, when the machine is connected to
hot water consumed less electrical energy to
heat water and program time is shortened.
START (T2)
Super rinse
S:0 Super Rinse, default
PROG (T1) S:1 Super Rinse on. Adding two extra rinses.
START (T2)
Total restart
r:0 No restart on the next press T2, default
PROG (T1) r:1 Total restart at the next press T2
START (T2)
DW90.1, DW90.1 OEM, DW90.2
After power on, wait until LCD is turned on. Then, within 5sec, press first T1 and
directly after T2. Hold both buttons pressed during 5sec to enter service menu.
START (T2)
Failure
CU Date code xxxx Control unit manufacturing date:year week
Software xxx Software version
PROG (T1) 3 FAIL. xxxx Last failure
2 FAIL. xxxx 2nd last failure
1 FAIL. xxxx 3rd last failure
START (T2)
Diagnostic
Testing No component on
Testing Valve A: XXX Mix valve on and inlet valve on (1 sec delay
between mix valve and inlet valve), flow in
pulses(XXX) by flow meter
Testing Valve B: XXX Inlet valve on (1 sec delay), flow in pulses(XXX)
by flow meter
PROG (T1) Testing Salt Salt valve on
Testing Dispenser Kombi dispenser on
Testing Cirk: XXV Circulation pump on and the water diverter
valve(if present) shall change between position
1 and 3 every 30 second, turbidity(XX) in Volt
Testing Heater: XX°C Circulation pump and heater on until max 75°C,
temp displayed in °C or °F according to
machine setup
Testing Fan: XXXX Fan and wax actuator on, humidity value(XXXX
Hz)
Testing TDE TDE fan on and TDE heater on
Testaing Drain: XXV drain pump on , pressure sensor value(XX) in
Volt
START (T2)
Water inlet
Water volume 0 Normal water intake, default
Water volume +5% Water intake increased +5%
Water volume +10% Water intake increased +10%
Water volume +15% Water intake increased +15%
PROG (T1) Water volume Time 0 Time, flow meter disconnected, inlet time: no of
pulses x 0.068 [s]
Water volume Time +5% Timed water intake increased +5%
Water volume Time +10% Timed water intake increased +10%
Water volume Time +15% Timed water intake increased +15%
START (T2)
LCD-cont
Contrast 0 LCD-contrast 0
Contrast +1 LCD contrast +1
PROG (T1) Contrast +2 LCD contrast +2
Contrast -1 LCD contrast -1
START (T2)
TDE
Turbo Drying On Turbo Drying Express On
PROG (T1) Turbo Drying Off Turbo Drying Express off
START (T2)
Fan seq.
Fan Off No fan sequence during wash cycle
PROG (T1) Fan 1 On Fan sequence during the wash cycle but not
in Normal program, the default setting
Fan 2 On Fan in sequence during the all wash cycles
START (T2)
DUO
DUO Off DUO Off
PROG (T1) DUO On DUO On, to activate frogram like Sani, Pots
& pans
START (T2)
Region
Region EU Region Europa, default setting
Region US Region USA
PROG (T1) Region AU Region Australien
START (T2)
DW90.3
To enter service menu, press T1 and T2 at power on.
T5 T1
T2
T4
T3