Warning
The safety wire (green-yellow) is
connected to the appliance’s terminal
and must be connected to the
ground lead of the electrical set-up.
In the case of connection to an electric
wall socket, it must remain accessible
after installation.
The fuse in your set-up must be
10 amperes.
If the power cable is damaged, it must
be replaced by the manufacturer, its
After-Sales Service Department or a
similarly qualified person to avoid
danger.
Warning
If the power cable is damaged, it
should be replaced by the
manufacturer, its after-sales service
department or by a qualified person to
avoid danger.
12
For the fitter
Neutral
Earth
Live
N
L
Green/yellow
Blue
Black-grey
Brown
Hook-up of 220-240V~
32A
Neutral
Earth
Live
N
L1
L2
Blue
Green/yellow
Black-grey
Brown
For a 400 V 2N triphase connection, if your
hob malfunctions, check that the neutral
conductor is properly connected.
Electrical connection
These hobs must be connected to the
mains using a socket in compliance with
publication IEC 60083 or an all-pole circuit-
breaker device in compliance with the
installation rules in force.
When power is first supplied to your hob,
or after an extended power cut, an
indicator light will appear on the control
panel. Wait for 30 seconds approximately
until this information disappears before
using your hob (This display is normal and
it is intended, if applicable, for your after-
sales service. In all cases, the user of the
hob should disregard it).
Hook-up of 400V 2N~ - 16A
Separate the 2 phase wires (L1 and L2)
before connection.
Neutral
Earth
Live
N
L
Green/yellow
Blue
Brown
16A for model 803HI16322
32A for model 803HI18322
Kommentare zu diesen Handbüchern